What is the difference between heat exchanger and condenser




















Condenser is a kind of refrigeration system. It is a kind of heat exchanger. It can convert gas or vapor into liquid, and transfer the heat in the pipe to the air near the pipe in a fast way. The working process of the condenser is an exothermic process, so the condenser temperature is high. The power plant uses a number of condensers to condense the vapors from the turbine.

A condenser is used in a freezer to condense refrigeration vapors such as ammonia and Freon. This also ensures that the growth of bacteria does not pose a problem and it will not so long as the temperature is steadily and accurately maintained. This is a very crucial part of cold storage. So this means that the products are being stored in a refrigerated courier and the temperature is kept exactly the same for the whole duration of the trip, never changing.

These cold storage services will process your goods as well as package and deliver these products to just about anywhere so long as it is in its refrigerated courier.

These cold storages are used a lot to store perishable food items like fruits and vegetables and fresh meat also. A lot of these companies will not be able to function without the use of cold storages. These storage systems are crucial to a lot of businesses today because the majority of these companies require the use of an environment whose temperature is precisely controlled.

There are others to name and can be found on the website listed below. Cold storage as you can see has its place in the consumer business and is deemed a very important and necessary part of everyday business. Web Design By. A condenser is simply a heat exchanger. It compresses refrigerants into a hot gas to then condense them into a liquid. Majorly condenser is used to cool the required vapor and heat exchanger is used to heat the required liquid.

Surface condenser is a heat exchanger in which latent heat only absorbed by the cooling media and heat exchange mostly takes place on availble just surface of the tube bundle. Overhead condenses is also a heat exchanger in which latent heat and somewhat sensible heat also removed from the fluid.

Calorifer is a heat exchanger, with a specific of air or other gas preheat. Usually is directly in a Duct installed. Heat Exchanger usually is separate unit. This liquid can then be circulated through a heat exchanger to cool air or equipment as required.

A condenser boiler has a primary and a secondary heat exchanger. Fuel that is used to simply warm up water can be sent to the secondary heat exchanger and reused. This is a substantially more efficient use of energy.

A condenser is a form of heat exchanger. In the condenser, the coolant condenses from a gas to a liquid, and loses heat energy to the surroundings like air being blown across it. By using the heat exchanger design principal. A heat exchanger with straight tubes in a shell that can normally be mechanically cleaned. Heat is absorbed by the refrigerant liquid inside the fridge, and rejected by the heat exchanger on the back of it.

Similar function to a car radiator or an air conditioning condenser. The heat from the fluid is pressurized to build up heat. As it passes through the heat exchanger, the heat from the heated fluid is exhanged to the ambient air which passes through the cooling fins.

The use of the LMTD arises straightforwardly from the analysis of a heat exchanger with constant flow rate and fluid thermal properties. It is a simple method to approximated the temperature diving force in a heat exchanger. The LMTD is a logarithmic average of the temperature difference between the hot and cold streams at each end of the exchanger. The larger the LMTD, the more heat is transferred.

A condenser tumble dryer works the same as a regular tumble dryer except the condenser dryer uses a heat exchanger to cool the air and condense the water vapor into a collection pipe. Refrigerant is pumped out of the compressor as a high pressure vapor, and it goes into the condenser inlet as such.

The condenser acts as a heat exchanger, transferring heat from the refrigerant to the air which passes over the condenser fins. While in the condenser, the refrigerant will change state from a high pressure vapor to a high pressure liquid, then it moves on to the receiver-drier on a thermal expansion valve system or the orifice tube on a fixed orifice tube system. The duty of a heat exchanger can be defined in an easy way as "The amount of heat exchanged from a fluid at a higher temperature to the fluid at lower temperature in unit time by a heat exchanger is called its duty".

The company started its functioning in, with a strong background in heat exchanger manufacturing. Our well-experienced and dedicated employees consistently thrive to serve our customers with the best heat exchanger solution. A heat exchanger. Plate heat exchangers are used in combination boilers, also sometimes referred to a 'combi-boilers'. The plate heat exchanger is found inside the hot water section and uses metal plates to move heat between two fluids.

Both the cooler and heat exchanger perform the same function as they remove heat from the engine.



0コメント